Entry DOI: doi:10.13018/BMSE001167
Data source: National Magnetic Resonance Facility at Madison - Maria Nesterova, Lawrence J. Clos, Christopher Stancic, Mark E. Anderson, John L. Markley
NMR-STAR file:
bmse001167.strNMR-STAR
interactive viewerStructure file (mol/sdf):
bmse001167.molAll files for
bmse001167Time Domain Data:
bmse001167.zipView the GISSMO record for this entry.
Sample and instrument details are given with the spectrum
Set 1
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
Atom ID | Value | Ambiguity Code |
---|---|---|
C12 | 102.9208 | 1 |
C11 | 156.0503 | 1 |
C15 | 146.6799 | 1 |
C13 | 175.7942 | 1 |
C14 | 135.5559 | 1 |
C7 | 121.5426 | 1 |
C10 | 160.5896 | 1 |
C6 | 93.36 | 1 |
C9 | 163.769 | 1 |
C5 | 98.0794 | 1 |
C1 | 129.4025 | 1 |
C2 | 129.4025 | 1 |
C3 | 115.3269 | 1 |
C4 | 115.3269 | 1 |
C8 | 159.0783 | 1 |
H31 | 6.4352 | 1 |
H30 | 6.1933 | 1 |
H29 | 8.0569 | 1 |
H28 | 8.0569 | 1 |
H27 | 6.9294 | 1 |
H26 | 6.9294 | 1 |
1: 1D 1H
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
2: 2D 1H-1H TOCSY
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
3: 1D 13C
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
4: 1D DEPT90
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
5: 1D DEPT135
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
6: 2D 1H-13C HSQC
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
7: 2D 1H-13C HSQC SW small
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
8: 2D 1H-13C HMBC
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
9: 2D 1H-1H COSY
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
10: 2D 1H-13C HSQC-TOCSY-ADIA
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz