Entry DOI: doi:10.13018/BMSE001124
Data source: National Magnetic Resonance Facility at Madison - Maria Nesterova, Lawrence J. Clos, Christopher Stancic, Mark E. Anderson, John L. Markley
NMR-STAR file:
bmse001124.strNMR-STAR
interactive viewerStructure file (mol/sdf):
bmse001124.molAll files for
bmse001124Time Domain Data:
bmse001124.zipView the GISSMO record for this entry.
Sample and instrument details are given with the spectrum
Set 1
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
Atom ID | Value | Ambiguity Code |
---|---|---|
C15 | 103.7305 | 1 |
C14 | 157.3354 | 1 |
C12 | 181.7984 | 1 |
C13 | 163.7561 | 1 |
C11 | 161.4868 | 1 |
C7 | 102.8626 | 1 |
C6 | 93.9989 | 1 |
C8 | 121.1968 | 1 |
C10 | 164.1675 | 1 |
C5 | 98.8636 | 1 |
C1 | 128.5221 | 1 |
C2 | 128.5221 | 1 |
C3 | 115.9868 | 1 |
C4 | 115.9868 | 1 |
C9 | 161.207 | 1 |
H27 | 6.7856 | 1 |
H26 | 6.4827 | 1 |
H25 | 6.1976 | 1 |
H21 | 7.9311 | 1 |
H22 | 7.9311 | 1 |
H23 | 6.9282 | 1 |
H24 | 6.9282 | 1 |
1: 1D 1H
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
2: 2D 1H-1H TOCSY
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
3: 1D 13C
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
4: 1D DEPT90
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
5: 1D DEPT135
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
6: 2D 1H-13C HSQC
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
7: 2D 1H-13C HSQC SW small
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
8: 2D 1H-13C HMBC
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
9: 2D 1H-1H COSY
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz
10: 2D 1H-13C HSQC-TOCSY-ADIA
Sample: 100mM in DMSO, ref: TMS
Conditions: temperature: 298K
Spectrometer: Bruker Avance III - 500MHz